高(gao)(gao)低溫(wen)試驗(yan)(yan)(yan)箱(xiang)系(xi)列主(zhu)要(yao)應用(yong)于(yu)(yu)工(gong)業產(chan)品高(gao)(gao)、低溫(wen)的(de)(de)可靠性(xing)試驗(yan)(yan)(yan)。對(dui)于(yu)(yu)汽車摩托、電工(gong)電子、航天航空、高(gao)(gao)等(deng)學府、科研單(dan)位(wei)、電力巨(ju)頭等(deng)有(you)關產(chan)品的(de)(de)零部件及(ji)材料在高(gao)(gao)、低情況(kuang)下或(huo)者循(xun)環變化的(de)(de)情況(kuang)下,用(yong)于(yu)(yu)檢測機(ji)器各項性(xing)能(neng)的(de)(de)指標。高(gao)(gao)低溫(wen)試驗(yan)(yan)(yan)箱(xiang)運用(yong)于(yu)(yu)較寬范圍的(de)(de)溫(wen)度控制(zhi)(zhi)范圍,其性(xing)能(neng)指標能(neng)夠達到國家標準。那么(me)高(gao)(gao)低溫(wen)試驗(yan)(yan)(yan)箱(xiang)在實際生產(chan)有(you)這么(me)多的(de)(de)用(yong)途!高(gao)(gao)低溫(wen)試驗(yan)(yan)(yan)箱(xiang)系(xi)列在實際生產(chan)運用(yong)的(de)(de)制(zhi)(zhi)冷(leng)方式(shi)又(you)有(you)哪幾(ji)種(zhong)呢?下面(mian)將深入講解高(gao)(gao)低溫(wen)試驗(yan)(yan)(yan)箱(xiang)制(zhi)(zhi)冷(leng)系(xi)統。
1、冷卻(que)方式:風冷;
2、制冷(leng)劑:采用制冷(leng)劑R502(低壓(ya)循環);
3、高低溫試(shi)驗箱制冷(leng)輔助件:風冷(leng)式盤管冷(leng)凝器(qi)、鰭片式多段式蒸發器(qi),主要制冷(leng)配件及控制器(qi)件均采用(yong)進口原件。
4、制(zhi)(zhi)冷(leng)(leng)系統的(de)(de)設(she)計應有能(neng)(neng)量調節技術,一(yi)種行(xing)之(zhi)有效的(de)(de)處理(li)方式既能(neng)(neng)保證在制(zhi)(zhi)冷(leng)(leng)機組正常(chang)運(yun)行(xing)的(de)(de)情(qing)況下又能(neng)(neng)對制(zhi)(zhi)冷(leng)(leng)系統的(de)(de)能(neng)(neng)耗及制(zhi)(zhi)冷(leng)(leng)量進行(xing)有效的(de)(de)調節,使(shi)制(zhi)(zhi)冷(leng)(leng)系統的(de)(de)運(yun)行(xing)費用和故障率下降到較為經濟的(de)(de)狀態;
5、制冷(leng)壓縮機:為保證試(shi)驗箱對降溫(wen)速率(lv)和(he)可達最低溫(wen)度的(de)要求,其連接容器(qi)為蒸(zheng)(zheng)發冷(leng)凝器(qi),蒸(zheng)(zheng)發冷(leng)凝器(qi)的(de)功能為將低壓循環的(de)蒸(zheng)(zheng)發器(qi)作(zuo)為高壓循環的(de)冷(leng)凝器(qi)之(zhi)用。
試(shi)驗箱制冷劑泄漏的(de)故障處理
高低(di)溫(wen)(wen)(wen)試驗(yan)箱的(de)(de)(de)壓(ya)縮機(ji)從(cong)吸(xi)氣(qi)管吸(xi)入低(di)溫(wen)(wen)(wen)低(di)壓(ya)的(de)(de)(de)制(zhi)冷(leng)(leng)劑(ji)氣(qi)體,通過電機(ji)運轉帶動(dong)活塞對其(qi)進行(xing)壓(ya)縮后,向排(pai)氣(qi)管排(pai)出高溫(wen)(wen)(wen)高壓(ya)的(de)(de)(de)制(zhi)冷(leng)(leng)劑(ji)氣(qi)體,為制(zhi)冷(leng)(leng)循(xun)環提供動(dong)力,從(cong)而實(shi)現壓(ya)縮——冷(leng)(leng)凝——膨脹——蒸發(吸(xi)熱(re))的(de)(de)(de)制(zhi)冷(leng)(leng)循(xun)環。如(ru)果制(zhi)冷(leng)(leng)劑(ji)發生泄漏如(ru)何(he)處理呢?
首先,觀測高低(di)溫試驗箱背部的壓(ya)力(li)表,看(kan)壓(ya)力(li)是(shi)否(fou)在正常(chang)范圍值(zhi)內,如果低(di)于正常(chang)值(zhi),則說明制(zhi)冷劑(ji)發(fa)生泄(xie)漏,要對高低(di)溫試驗箱的制(zhi)冷系統(tong)進行檢漏,向銅(tong)管(guan)內輸入高壓(ya)氮氣(qi),用(yong)檢漏儀和(he)肥皂(zao)水相(xiang)結合(he)的辦法來檢查漏點(dian)(dian),通常(chang)漏點(dian)(dian)只有(you)(you)一處(chu)(chu),有(you)(you)時會有(you)(you)多(duo)處(chu)(chu)漏點(dian)(dian),比較(jiao)少見。找到漏點(dian)(dian)后,用(yong)氧焊將泄(xie)漏處(chu)(chu)焊接密封,再對制(zhi)冷系統(tong)進行充(chong)氮氣(qi),進行48小時保(bao)壓(ya),保(bao)壓(ya)過程中發(fa)現壓(ya)力(li)表指針沒(mei)有(you)(you)變化,說明漏點(dian)(dian)已經補焊正常(chang),釋放氮氣(qi),向系統(tong)充(chong)入環保(bao)型制(zhi)冷劑(ji)R404和(he)R23,制(zhi)冷系統(tong)即可恢復正常(chang)工作。
標(biao)準(zhun)型高低(di)溫(wen)試(shi)(shi)驗(yan)箱和恒(heng)溫(wen)恒(heng)濕試(shi)(shi)驗(yan)箱均(jun)采用風(feng)冷(leng)壓縮機進行(xing)制(zhi)冷(leng),其工作原(yuan)理(li)和空調制(zhi)冷(leng)的(de)原(yuan)理(li)是一樣的(de),在制(zhi)冷(leng)過程中會采用冷(leng)媒進行(xing)制(zhi)冷(leng),一旦制(zhi)冷(leng)劑(ji)發生泄漏,會導致試(shi)(shi)驗(yan)箱停擺,不能(neng)進行(xing)低(di)溫(wen)試(shi)(shi)驗(yan)和濕度(du)小于(yu)85%RH的(de)濕熱(re)試(shi)(shi)驗(yan)。
東莞恒(heng)工設備是從事恒(heng)溫(wen)恒(heng)濕試(shi)(shi)驗(yan)箱,步(bu)入式(shi)環境(jing)試(shi)(shi)驗(yan)室,快速溫(wen)變試(shi)(shi)驗(yan)箱,冷熱(re)沖擊試(shi)(shi)驗(yan)箱,高低(di)溫(wen)低(di)氣(qi)壓試(shi)(shi)驗(yan)箱等,業務聯系:潘先(xian)生