1.冷熱沖擊試驗(yan)箱在高溫(wen)(wen)試驗(yan)中,如(ru)溫(wen)(wen)度(du)變化達不到試驗(yan)溫(wen)(wen)度(du)值時,可以檢查電(dian)器系(xi)統(tong),逐一排除故障。如(ru)溫(wen)(wen)度(du)升(sheng)得很慢,就(jiu)要查看風(feng)循環(huan)系(xi)統(tong),看一下風(feng)循環(huan)的(de)調(diao)節(jie)擋(dang)板是(shi)否開啟正常,反之,就(jiu)檢查風(feng)循環(huan)的(de)電(dian)機(ji)運轉(zhuan)是(shi)否正常。如(ru)溫(wen)(wen)度(du)過(guo)沖厲害那么就(jiu)需(xu)要整定PID的(de)設置參數。如(ru)果溫(wen)(wen)度(du)直接(jie)上升(sheng),過(guo)溫(wen)(wen)保護,那么,控制(zhi)器出故障,須更換(huan)控制(zhi)儀表(biao)。
2.冷(leng)(leng)熱沖擊(ji)試(shi)驗(yan)箱(xiang)低(di)溫(wen)達不到試(shi)驗(yan)的(de)(de)(de)(de)指標,那你就要觀察(cha)溫(wen)度的(de)(de)(de)(de)變化,是(shi)(shi)(shi)溫(wen)度降(jiang)的(de)(de)(de)(de)很慢(man),還是(shi)(shi)(shi)溫(wen)度到一(yi)(yi)定值后(hou)(hou)溫(wen)度有回(hui)升的(de)(de)(de)(de)趨勢,前者就要檢(jian)查一(yi)(yi)下(xia),做低(di)溫(wen)試(shi)驗(yan)前是(shi)(shi)(shi)否(fou)將工作(zuo)室(shi)烘干,使(shi)(shi)工作(zuo)室(shi)保持干燥后(hou)(hou)再將試(shi)驗(yan)樣品放入工作(zuo)室(shi)內再做試(shi)驗(yan),工作(zuo)室(shi)內的(de)(de)(de)(de)試(shi)驗(yan)樣品是(shi)(shi)(shi)否(fou)放置的(de)(de)(de)(de)過多,使(shi)(shi)工作(zuo)室(shi)內的(de)(de)(de)(de)風(feng)不能充分(fen)循環(huan),在排除上述原因后(hou)(hou),就要考慮是(shi)(shi)(shi)否(fou)是(shi)(shi)(shi)制冷(leng)(leng)系統(tong)中的(de)(de)(de)(de)故障了,這樣就要請廠(chang)家的(de)(de)(de)(de)專業人員(yuan)進(jin)行檢(jian)修。后(hou)(hou)者的(de)(de)(de)(de)現象(xiang)是(shi)(shi)(shi)設(she)備(bei)的(de)(de)(de)(de)使(shi)(shi)用(yong)環(huan)境(jing)不好(hao)所致,設(she)備(bei)放置的(de)(de)(de)(de)環(huan)境(jing)溫(wen)度,放置的(de)(de)(de)(de)位(wei)置(箱(xiang)體后(hou)(hou)與墻的(de)(de)(de)(de)距離)要滿足(zu)要求(在設(she)備(bei)操作(zuo)使(shi)(shi)用(yong)說明中都有規定)。
3.在做濕(shi)(shi)(shi)熱試(shi)驗中(zhong)(zhong)(zhong),出現(xian)實際濕(shi)(shi)(shi)度會達(da)到(dao)100%或(huo)者實際濕(shi)(shi)(shi)度與目標濕(shi)(shi)(shi)度相差(cha)很大(da),數值低得很多,前者的(de)(de)現(xian)象:可能是(shi)(shi)濕(shi)(shi)(shi)球(qiu)傳感器上(shang)(shang)的(de)(de)紗(sha)(sha)布(bu)干燥引(yin)起,那就(jiu)(jiu)要(yao)檢查濕(shi)(shi)(shi)球(qiu)傳感器的(de)(de)水(shui)(shui)(shui)槽中(zhong)(zhong)(zhong)是(shi)(shi)否缺水(shui)(shui)(shui),水(shui)(shui)(shui)槽中(zhong)(zhong)(zhong)的(de)(de)水(shui)(shui)(shui)位(wei)(wei)(wei)(wei)是(shi)(shi)由(you)一水(shui)(shui)(shui)位(wei)(wei)(wei)(wei)控(kong)制(zhi)器自(zi)動控(kong)制(zhi)的(de)(de),查水(shui)(shui)(shui)位(wei)(wei)(wei)(wei)控(kong)制(zhi)器供(gong)水(shui)(shui)(shui)系(xi)統(tong)(tong)是(shi)(shi)否供(gong)水(shui)(shui)(shui)正(zheng)(zheng)常(chang),水(shui)(shui)(shui)位(wei)(wei)(wei)(wei)控(kong)制(zhi)器工(gong)作是(shi)(shi)否正(zheng)(zheng)常(chang)。另(ling)一種可能就(jiu)(jiu)是(shi)(shi)濕(shi)(shi)(shi)球(qiu)紗(sha)(sha)布(bu)因(yin)使用時間長,或(huo)供(gong)水(shui)(shui)(shui)水(shui)(shui)(shui)質(zhi)純凈度的(de)(de)原因(yin),會使紗(sha)(sha)布(bu)變硬,使紗(sha)(sha)布(bu)無法吸收水(shui)(shui)(shui)份而干燥,只要(yao)更換或(huo)清洗(xi)紗(sha)(sha)布(bu)即(ji)可排(pai)除以上(shang)(shang)現(xian)象。后(hou)者的(de)(de)現(xian)象主要(yao)是(shi)(shi)加濕(shi)(shi)(shi)系(xi)統(tong)(tong)不工(gong)作,查看加濕(shi)(shi)(shi)系(xi)統(tong)(tong)的(de)(de)供(gong)水(shui)(shui)(shui)系(xi)統(tong)(tong),供(gong)水(shui)(shui)(shui)系(xi)統(tong)(tong)內是(shi)(shi)否有一定的(de)(de)水(shui)(shui)(shui)量,控(kong)制(zhi)加濕(shi)(shi)(shi)鍋爐水(shui)(shui)(shui)位(wei)(wei)(wei)(wei)的(de)(de)水(shui)(shui)(shui)位(wei)(wei)(wei)(wei)控(kong)制(zhi)是(shi)(shi)否正(zheng)(zheng)常(chang),加濕(shi)(shi)(shi)鍋爐內的(de)(de)水(shui)(shui)(shui)位(wei)(wei)(wei)(wei)是(shi)(shi)否正(zheng)(zheng)常(chang)。如以上(shang)(shang)一切(qie)都正(zheng)(zheng)常(chang),那就(jiu)(jiu)要(yao)檢查電器控(kong)制(zhi)系(xi)統(tong)(tong),這要(yao)請專(zhuan)業維修人員進行檢修。
4.設備在(zai)試驗運行(xing)(xing)過程中突然出(chu)現(xian)(xian)故(gu)(gu)障時,控制儀(yi)表上出(chu)現(xian)(xian)對應的(de)(de)故(gu)(gu)障顯示提示并有(you)聲訊(xun)報警提示。操作(zuo)人(ren)員(yuan)可以(yi)對照設備的(de)(de)操作(zuo)使用(yong)中的(de)(de)故(gu)(gu)障排除(chu)一章中快(kuai)速檢查出(chu)屬于哪一類(lei)故(gu)(gu)障,即可請專(zhuan)業(ye)人(ren)員(yuan)快(kuai)速排除(chu)故(gu)(gu)障,以(yi)確保試驗的(de)(de)正常(chang)進行(xing)(xing)。其(qi)它(ta)環境試驗設備在(zai)使用(yong)中還會有(you)其(qi)它(ta)的(de)(de)現(xian)(xian)象,那就要具體現(xian)(xian)象,具體分(fen)析和排除(chu)。
環境試(shi)驗設備還要定(ding)期(qi)進(jin)行維護(hu)保養(yang),制冷(leng)系統的(de)冷(leng)凝器(qi)定(ding)期(qi)清理,對于活(huo)動部件應(ying)按說明書加(jia)油潤滑,電器(qi)控制系統定(ding)期(qi)維護(hu)檢查等等,這(zhe)些工作是必不可(ke)少(shao)的(de)。
如何(he)解決恒溫恒濕(shi)試驗箱的一些小問題
當把恒溫(wen)恒濕(shi)試驗(yan)箱(xiang)買回去使用之(zhi)后(hou),使用的(de)(de)時間越長,那么(me)出現的(de)(de)問題(ti)也就(jiu)越多,因為(wei)誰也無法保證設(she)備能夠使用多長時間,因為(wei)著不僅僅跟生(sheng)產(chan)廠家有(you)關,還跟后(hou)期(qi)的(de)(de)維(wei)護有(you)關。
該(gai)設備在試(shi)驗(yan)的(de)(de)時(shi)候溫度是一個關鍵的(de)(de)試(shi)驗(yan)數據(ju),那么出(chu)現溫度不(bu)對的(de)(de)情(qing)況的(de)(de)時(shi)候,我們(men)可以(yi)(yi)先檢查電器系(xi)統,并且一一的(de)(de)將故障排除。如(ru)果是出(chu)現溫度升溫很慢的(de)(de)情(qing)況,就是風(feng)循環的(de)(de)問(wen)題(ti)了(le),可以(yi)(yi)檢查風(feng)循環的(de)(de)調(diao)節擋板或者電機(ji)哪里(li)沒有正(zheng)常的(de)(de)工(gong)作(zuo)。若在經一段長時(shi)間的(de)(de)使用之后(hou),紗(sha)(sha)布(bu)會(hui)(hui)吸收雜(za)質,從而使紗(sha)(sha)布(bu)變硬,這時(shi)就需要更換(huan)干凈的(de)(de)紗(sha)(sha)布(bu)了(le)。紗(sha)(sha)布(bu)出(chu)現問(wen)題(ti)會(hui)(hui)引起(qi)濕(shi)度不(bu)大標的(de)(de)情(qing)況。如(ru)果水(shui)(shui)箱內的(de)(de)水(shui)(shui)不(bu)夠,那么也是會(hui)(hui)引起(qi)濕(shi)度不(bu)達標的(de)(de)情(qing)況的(de)(de),所以(yi)(yi)需要把(ba)水(shui)(shui)補充滿就可以(yi)(yi)了(le)。
文章來源:東莞恒工(gong)設備有限(xian)公司 業務聯系:潘先生(sheng)